Guardian Fall Protection Issues Stop Use Notice


6/28/2006
As a result of Guardian Fall Protection's dedication to providing superior products and a total commitment to safety, Guardian has determined that certain Edge Series Retractable lifeline(s) require factory inspection or in-the-field inspection by a Guardian Territory Manager.

Guardian has issued a 'Stop Use and Inspection' notice on the cable Guardian Edge Series Retractables 20ft. and longer (this notice does not affect the Edge 11ft. models or the Edge 20ft. web models). If a Guardian Territory Manager is unable to inspect the unit in the field the affected units must be returned to the factory for inspection.


Required Action for Distributor:

1. Identify customers who have purchased the affected by/involved units. Guardian has provided a list of units purchased by your company to include affected Serial Numbers and Drop Ship information. If you prefer, on your behalf, Guardian can contact your end users and arrange return of affected units or schedule a Guardian Territory Manager to inspect the affected units.

2. Send a copy of the 'Stop Use and Inspection' notice (forwarded by Guardian) to the users you have identified by June 1, 2006.

3. Remove inventory affected by this 'Stop Use and Inspection' notice and take the following steps:


Required Action for Customers with Affected Units

Only Guardian Territory Managers are authorized to field-inspect the units and issue Certificates of Inspection on-site. All other inspections shall occur by sending the Edge Series Retractable Lifelines on this notice to Guardian's Kent, WA factory.

Please contact your Guardian Territory Manager to arrange an inspection. If you have any question please contact Guardian at 800-466-6385.


Return of Affected Units to Guardian Factory:

Distributors and End-Users with affected units are instructed to contact Guardian Customer Service if they have any questions. Guardian will issue a Return Inspection Number (RIN Number) to facilitate and expedite the inspection process. Freight will be paid by Guardian.


MODELS AFFECTED BY/INVOLVED In 'Stop Use and Inspection Notice:'

10910, Edge 20ft. cable retractable
10912, Edge 25ft. cable retractable
10915, Edge 30ft. cable retractable

Some 20ft., 25ft., and 30ft. models may have been marked on Invoices or Packing Slips as Item I.D.'s:

09994, 109 - - - Edge Series Cable Retractable
09992, 109 - - - Edge Series Cable Retractable
09990, 109 - - - Edge Series Cable Retractable







Back

       
Workplace Safety Experts, Construction, Training, OSHA, Inspections

Help with Safety Article Search




Click to verify BBB accreditation and to see a BBB report.


6500 Technology Center Drive
Suite 200
Indianapolis, IN 46278
Directions
Workplace Safety Construction Consultants
safety newsletter rss Rss Feed
Work for the Best
Ask a question
Privacy Statement